Review





Similar Products

94
Multi Sciences (Lianke) Biotech Co Ltd human ctni elisa kit
Human Ctni Elisa Kit, supplied by Multi Sciences (Lianke) Biotech Co Ltd, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ctni+elisa+kit/Human+cTnI+ELISA+Kit/pm40616070-63-20-24
Average 94 stars, based on 1 article reviews
human ctni elisa kit - by Bioz Stars, 2026-11
94/100 stars
  Buy from Supplier

94
ABclonal Biotechnology ctni elisa kit
a The workflow diagram of the ECLD. When the MNs are inserted into ISF, the micro-electrochemical workstation applies voltage to the MN area via PCB, the PMT detects the light signal and the photon counter performs photon counting, then the data is transmitted to the control and display module. b The exploded view of the ECLD detection module. The ECLD mainly consists of a PMT, a micro-electrochemical workstation, an outer housing, and a flexible rubber ring. It can display the real-time changes of the tested biomarkers either through a monitor or by transmitting to a mobile phone via Bluetooth. c Construction of an ECL MN Monitoring System. The porous MNs are constructed through 3D printing. Metal targets are sputtered onto different functional areas of the MNs via ion sputtering for surface modification. After surface modification, the MNs are integrated with a home-made ECL instrument for real-time monitoring in live animals. d Schematic diagram of the integrated MN sensing. It demonstrates the protein sensing mode after the MNs are inserted into ISF. The Y-shaped probe with Fc tag, formed by dual aptamer hybridization, binds to AMI-related antigens, leading to the release of Fc single chains, thereby achieving ECL signal recovery. AMI-related antigens include <t>cTnI,</t> NT-proBNP, D-dimer, myo, HSA and cTnT.
Ctni Elisa Kit, supplied by ABclonal Biotechnology, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ctni+elisa+kit/TNNI3+Rabbit+pAb/pmc13376637-394-11-17
Average 94 stars, based on 1 article reviews
ctni elisa kit - by Bioz Stars, 2026-11
94/100 stars
  Buy from Supplier

94
Cusabio csb e08718h mouse ctni elisa kit solarbio
a The workflow diagram of the ECLD. When the MNs are inserted into ISF, the micro-electrochemical workstation applies voltage to the MN area via PCB, the PMT detects the light signal and the photon counter performs photon counting, then the data is transmitted to the control and display module. b The exploded view of the ECLD detection module. The ECLD mainly consists of a PMT, a micro-electrochemical workstation, an outer housing, and a flexible rubber ring. It can display the real-time changes of the tested biomarkers either through a monitor or by transmitting to a mobile phone via Bluetooth. c Construction of an ECL MN Monitoring System. The porous MNs are constructed through 3D printing. Metal targets are sputtered onto different functional areas of the MNs via ion sputtering for surface modification. After surface modification, the MNs are integrated with a home-made ECL instrument for real-time monitoring in live animals. d Schematic diagram of the integrated MN sensing. It demonstrates the protein sensing mode after the MNs are inserted into ISF. The Y-shaped probe with Fc tag, formed by dual aptamer hybridization, binds to AMI-related antigens, leading to the release of Fc single chains, thereby achieving ECL signal recovery. AMI-related antigens include <t>cTnI,</t> NT-proBNP, D-dimer, myo, HSA and cTnT.
Csb E08718h Mouse Ctni Elisa Kit Solarbio, supplied by Cusabio, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ctni+elisa+kit/Human+granzyme+B+(GZMB)+ELISA+Kit/pm41861828-681-114-97
Average 94 stars, based on 1 article reviews
csb e08718h mouse ctni elisa kit solarbio - by Bioz Stars, 2026-11
94/100 stars
  Buy from Supplier

86
Nanjing Jiancheng Bioengineering Research Institute Co Ltd ctni
a The workflow diagram of the ECLD. When the MNs are inserted into ISF, the micro-electrochemical workstation applies voltage to the MN area via PCB, the PMT detects the light signal and the photon counter performs photon counting, then the data is transmitted to the control and display module. b The exploded view of the ECLD detection module. The ECLD mainly consists of a PMT, a micro-electrochemical workstation, an outer housing, and a flexible rubber ring. It can display the real-time changes of the tested biomarkers either through a monitor or by transmitting to a mobile phone via Bluetooth. c Construction of an ECL MN Monitoring System. The porous MNs are constructed through 3D printing. Metal targets are sputtered onto different functional areas of the MNs via ion sputtering for surface modification. After surface modification, the MNs are integrated with a home-made ECL instrument for real-time monitoring in live animals. d Schematic diagram of the integrated MN sensing. It demonstrates the protein sensing mode after the MNs are inserted into ISF. The Y-shaped probe with Fc tag, formed by dual aptamer hybridization, binds to AMI-related antigens, leading to the release of Fc single chains, thereby achieving ECL signal recovery. AMI-related antigens include <t>cTnI,</t> NT-proBNP, D-dimer, myo, HSA and cTnT.
Ctni, supplied by Nanjing Jiancheng Bioengineering Research Institute Co Ltd, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ctni+elisa+kit/cardiac+i+troponin/pm41828600-119-6-14
Average 86 stars, based on 1 article reviews
ctni - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

93
Elabscience Biotechnology ctni elisa kit
PEN treatment normalizes serum protein markers of cardiac injury (CK-MB, LDH, Cardiac troponin I) assessed by <t>ELISA.</t> Serum levels of cardiac markers were significantly increased by DOX, while PEN administration normalized them. DOX: Doxorubicin; PEN: Penicillamine; LDH: Lactic acid dehydrogenase; CK-MB: Creatine kinase-MB. *** p < 0.001, **** p < 0.0001, ns = non-significant.
Ctni Elisa Kit, supplied by Elabscience Biotechnology, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ctni+elisa+kit/Rat+TNNI3%2FcTn-I+(Troponin+I+Type+3/pmc12467753-108-42-45
Average 93 stars, based on 1 article reviews
ctni elisa kit - by Bioz Stars, 2026-11
93/100 stars
  Buy from Supplier

93
Elabscience Biotechnology mouse cardiac troponin i ctni elisa kit
PEN treatment normalizes serum protein markers of cardiac injury (CK-MB, LDH, Cardiac troponin I) assessed by <t>ELISA.</t> Serum levels of cardiac markers were significantly increased by DOX, while PEN administration normalized them. DOX: Doxorubicin; PEN: Penicillamine; LDH: Lactic acid dehydrogenase; CK-MB: Creatine kinase-MB. *** p < 0.001, **** p < 0.0001, ns = non-significant.
Mouse Cardiac Troponin I Ctni Elisa Kit, supplied by Elabscience Biotechnology, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ctni+elisa+kit/Mouse+Tn-I+(Troponin+I)+ELISA+Kit/10__1016_slash_j__phymed__2025__157317-60-1-11
Average 93 stars, based on 1 article reviews
mouse cardiac troponin i ctni elisa kit - by Bioz Stars, 2026-11
93/100 stars
  Buy from Supplier

86
Sunlong Biotech Co Ltd sheep ctni elisa kit
PEN treatment normalizes serum protein markers of cardiac injury (CK-MB, LDH, Cardiac troponin I) assessed by <t>ELISA.</t> Serum levels of cardiac markers were significantly increased by DOX, while PEN administration normalized them. DOX: Doxorubicin; PEN: Penicillamine; LDH: Lactic acid dehydrogenase; CK-MB: Creatine kinase-MB. *** p < 0.001, **** p < 0.0001, ns = non-significant.
Sheep Ctni Elisa Kit, supplied by Sunlong Biotech Co Ltd, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ctni+elisa+kit/elisa+kit+sandwich/pmc12390671-131-18-23
Average 86 stars, based on 1 article reviews
sheep ctni elisa kit - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

90
Elabscience Biotechnology elisa kits of cardiac troponin i (ctni)
PEN treatment normalizes serum protein markers of cardiac injury (CK-MB, LDH, Cardiac troponin I) assessed by <t>ELISA.</t> Serum levels of cardiac markers were significantly increased by DOX, while PEN administration normalized them. DOX: Doxorubicin; PEN: Penicillamine; LDH: Lactic acid dehydrogenase; CK-MB: Creatine kinase-MB. *** p < 0.001, **** p < 0.0001, ns = non-significant.
Elisa Kits Of Cardiac Troponin I (Ctni), supplied by Elabscience Biotechnology, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ctni+elisa+kit/elisa+kits+for+cardiac+troponin+i++ctni+/10__1002_slash_adfm__202501018-429-10-26
Average 90 stars, based on 1 article reviews
elisa kits of cardiac troponin i (ctni) - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


a The workflow diagram of the ECLD. When the MNs are inserted into ISF, the micro-electrochemical workstation applies voltage to the MN area via PCB, the PMT detects the light signal and the photon counter performs photon counting, then the data is transmitted to the control and display module. b The exploded view of the ECLD detection module. The ECLD mainly consists of a PMT, a micro-electrochemical workstation, an outer housing, and a flexible rubber ring. It can display the real-time changes of the tested biomarkers either through a monitor or by transmitting to a mobile phone via Bluetooth. c Construction of an ECL MN Monitoring System. The porous MNs are constructed through 3D printing. Metal targets are sputtered onto different functional areas of the MNs via ion sputtering for surface modification. After surface modification, the MNs are integrated with a home-made ECL instrument for real-time monitoring in live animals. d Schematic diagram of the integrated MN sensing. It demonstrates the protein sensing mode after the MNs are inserted into ISF. The Y-shaped probe with Fc tag, formed by dual aptamer hybridization, binds to AMI-related antigens, leading to the release of Fc single chains, thereby achieving ECL signal recovery. AMI-related antigens include cTnI, NT-proBNP, D-dimer, myo, HSA and cTnT.

Journal: Nature Communications

Article Title: In situ electrochemiluminescence microneedle device for real-time biomarker monitoring in vivo

doi: 10.1038/s41467-026-70686-8

Figure Lengend Snippet: a The workflow diagram of the ECLD. When the MNs are inserted into ISF, the micro-electrochemical workstation applies voltage to the MN area via PCB, the PMT detects the light signal and the photon counter performs photon counting, then the data is transmitted to the control and display module. b The exploded view of the ECLD detection module. The ECLD mainly consists of a PMT, a micro-electrochemical workstation, an outer housing, and a flexible rubber ring. It can display the real-time changes of the tested biomarkers either through a monitor or by transmitting to a mobile phone via Bluetooth. c Construction of an ECL MN Monitoring System. The porous MNs are constructed through 3D printing. Metal targets are sputtered onto different functional areas of the MNs via ion sputtering for surface modification. After surface modification, the MNs are integrated with a home-made ECL instrument for real-time monitoring in live animals. d Schematic diagram of the integrated MN sensing. It demonstrates the protein sensing mode after the MNs are inserted into ISF. The Y-shaped probe with Fc tag, formed by dual aptamer hybridization, binds to AMI-related antigens, leading to the release of Fc single chains, thereby achieving ECL signal recovery. AMI-related antigens include cTnI, NT-proBNP, D-dimer, myo, HSA and cTnT.

Article Snippet: Simulated interstitial fluid (Biochemazone, BZ254) was purchased from Chemazone Inc. (Canada). cTnI ELISA kit was obtained from ABclonal Biotechnology Co., Ltd. (Wuhan, China).

Techniques: Control, Construct, Functional Assay, Modification, Hybridization

a The crystal growth process of HOF-101. The monomer TCPPY was dissolved in DMF and then placed in an environment of acetone vapor to form HOF-101 crystals. After collection, the crystals were washed and dried for later use. b SEM image of HOF-101. The scale bar is 5 μm. c TEM image of HOF-101. d EDS mapping of C element. e EDS mapping of O element. The scale bars of TEM results are 2.5 μm. f XPS survey spectrum of HOF-101. g High-resolution XPS spectrum of C 1 s in HOF-101. h High-resolution XPS spectrum of O 1 s in HOF-101. i PAGE image of CP1, CP2, AP, L-Fc, and the Y-shaped probe. j 3D AFM image of AuNPs and after modification with Y-shaped probes. k The height variation of the sample surface. l Molecular Docking Simulation of the interaction between Y-shaped Probes and cTnI Antigen Molecules. m Four-parameter fitting curve of SPR. n SPR dynamic curves of the interaction between cTnI of different concentrations and Y-shaped probes. o The K D value between the Y-shaped probe and cTnI antigen molecules using the SPR method. p CV and q EIS methods of the sensing interface. GCE (curve a), HOF-101/AuNPs/CS/GCE (curve b), Y-shaped probe/HOF-101/AuNPs/CS/GCE (curve c), MCH/Y-probe/HOF-101/AuNPs/CS/GCE (curve d), cTnI/MCH/Y-probe/HOF-101/AuNPs/CS/GCE (curve e). The concentration of cTnI was 10 ng/mL.

Journal: Nature Communications

Article Title: In situ electrochemiluminescence microneedle device for real-time biomarker monitoring in vivo

doi: 10.1038/s41467-026-70686-8

Figure Lengend Snippet: a The crystal growth process of HOF-101. The monomer TCPPY was dissolved in DMF and then placed in an environment of acetone vapor to form HOF-101 crystals. After collection, the crystals were washed and dried for later use. b SEM image of HOF-101. The scale bar is 5 μm. c TEM image of HOF-101. d EDS mapping of C element. e EDS mapping of O element. The scale bars of TEM results are 2.5 μm. f XPS survey spectrum of HOF-101. g High-resolution XPS spectrum of C 1 s in HOF-101. h High-resolution XPS spectrum of O 1 s in HOF-101. i PAGE image of CP1, CP2, AP, L-Fc, and the Y-shaped probe. j 3D AFM image of AuNPs and after modification with Y-shaped probes. k The height variation of the sample surface. l Molecular Docking Simulation of the interaction between Y-shaped Probes and cTnI Antigen Molecules. m Four-parameter fitting curve of SPR. n SPR dynamic curves of the interaction between cTnI of different concentrations and Y-shaped probes. o The K D value between the Y-shaped probe and cTnI antigen molecules using the SPR method. p CV and q EIS methods of the sensing interface. GCE (curve a), HOF-101/AuNPs/CS/GCE (curve b), Y-shaped probe/HOF-101/AuNPs/CS/GCE (curve c), MCH/Y-probe/HOF-101/AuNPs/CS/GCE (curve d), cTnI/MCH/Y-probe/HOF-101/AuNPs/CS/GCE (curve e). The concentration of cTnI was 10 ng/mL.

Article Snippet: Simulated interstitial fluid (Biochemazone, BZ254) was purchased from Chemazone Inc. (Canada). cTnI ELISA kit was obtained from ABclonal Biotechnology Co., Ltd. (Wuhan, China).

Techniques: Modification, Concentration Assay

a The operation method of the ECLD test in vitro. The MNs are tightly integrated with the flexible PCB board through a fixture, and the PMT is placed on the back of the transparent MNs to detect the changes in the ECL signals of HOF-101 on the MN surface caused by cTnI molecules in the artificial ISF. b The 3D modeling diagram of the modified MN patch in the artificial ISF. c ECL signals of bare MNs, CS/MNs, AuNPs/ MNs, Ru(bpy) 3 2+ /MNs, and HOF-101/AuNPs/CS/ MNs, respectively. d The ECL signals of HOF-101/AuNPs/CS/MNs (curve a), Y-shaped probe/HOF-101/AuNPs/CS/ MNs (curve b), cTnI/MCH/Y-shaped probe/HOF-101/AuNPs/CS/ MNs (curve c). e The potential range of the ECL signal. The applied potential ranges were −1 V to +1 V, −2 V to +2 V, −3 V to +3 V, −4 V to +4 V, −5 V to +5 V, −6 V to +6 V, -7 V to +7 V, and −8 V to +8 V. The experiments were conducted in 0.1 M PBS (pH 7.4) with a scan rate of 1 V/s. The concentration of cTnI was 10 ng/mL. f ECL signals corresponding to cTnI concentrations of 10 ng/mL, 1 ng/mL, 100 pg/mL, 10 pg/mL, 1 pg/mL, 100 fg/mL, 10 fg/mL, and 0. The cTnI solutions were prepared in artificial ISF, and the experiments were conducted in 0.1 M PBS (pH 7.4) with a scan rate of 1 V/s and an applied potential range of −8 V to +8 V. g The linear relationship plot between ECL signals and the logarithm of cTnI concentration. h The specificity test of ECLD MNs incubated in blank artificial ISF, 1 μg/mL of D-dimer, 1 μg/mL of myo, 1 μg/mL of HSA, 10 ng/mL of cTnT, and a mixed solution containing 1 μg/mL of D-dimer, myo, HSA, cTnT, and 10 ng/mL of cTnI. i The repeatability test of the ECLD MNs in vitro for 15 days in artificial ISF containing 10 ng/mL of cTnI. Data presented as mean values ± SD, three parallel experiments were carried out every day. j The stability test of the ECLD MNs under continuous scanning for 25 cycles. k The radar chart of ECL signal quenching and recovery for ECLD MNs platform targeting NT-proBNP, HSA, myo, cTnT, and D-dimer. l ECL annihilation schematic diagram of HOF-101. m Cell viability of H9c2 cells treated with Y-shaped probes. n Cell viability of H9c2 cells treated with HOF-101.

Journal: Nature Communications

Article Title: In situ electrochemiluminescence microneedle device for real-time biomarker monitoring in vivo

doi: 10.1038/s41467-026-70686-8

Figure Lengend Snippet: a The operation method of the ECLD test in vitro. The MNs are tightly integrated with the flexible PCB board through a fixture, and the PMT is placed on the back of the transparent MNs to detect the changes in the ECL signals of HOF-101 on the MN surface caused by cTnI molecules in the artificial ISF. b The 3D modeling diagram of the modified MN patch in the artificial ISF. c ECL signals of bare MNs, CS/MNs, AuNPs/ MNs, Ru(bpy) 3 2+ /MNs, and HOF-101/AuNPs/CS/ MNs, respectively. d The ECL signals of HOF-101/AuNPs/CS/MNs (curve a), Y-shaped probe/HOF-101/AuNPs/CS/ MNs (curve b), cTnI/MCH/Y-shaped probe/HOF-101/AuNPs/CS/ MNs (curve c). e The potential range of the ECL signal. The applied potential ranges were −1 V to +1 V, −2 V to +2 V, −3 V to +3 V, −4 V to +4 V, −5 V to +5 V, −6 V to +6 V, -7 V to +7 V, and −8 V to +8 V. The experiments were conducted in 0.1 M PBS (pH 7.4) with a scan rate of 1 V/s. The concentration of cTnI was 10 ng/mL. f ECL signals corresponding to cTnI concentrations of 10 ng/mL, 1 ng/mL, 100 pg/mL, 10 pg/mL, 1 pg/mL, 100 fg/mL, 10 fg/mL, and 0. The cTnI solutions were prepared in artificial ISF, and the experiments were conducted in 0.1 M PBS (pH 7.4) with a scan rate of 1 V/s and an applied potential range of −8 V to +8 V. g The linear relationship plot between ECL signals and the logarithm of cTnI concentration. h The specificity test of ECLD MNs incubated in blank artificial ISF, 1 μg/mL of D-dimer, 1 μg/mL of myo, 1 μg/mL of HSA, 10 ng/mL of cTnT, and a mixed solution containing 1 μg/mL of D-dimer, myo, HSA, cTnT, and 10 ng/mL of cTnI. i The repeatability test of the ECLD MNs in vitro for 15 days in artificial ISF containing 10 ng/mL of cTnI. Data presented as mean values ± SD, three parallel experiments were carried out every day. j The stability test of the ECLD MNs under continuous scanning for 25 cycles. k The radar chart of ECL signal quenching and recovery for ECLD MNs platform targeting NT-proBNP, HSA, myo, cTnT, and D-dimer. l ECL annihilation schematic diagram of HOF-101. m Cell viability of H9c2 cells treated with Y-shaped probes. n Cell viability of H9c2 cells treated with HOF-101.

Article Snippet: Simulated interstitial fluid (Biochemazone, BZ254) was purchased from Chemazone Inc. (Canada). cTnI ELISA kit was obtained from ABclonal Biotechnology Co., Ltd. (Wuhan, China).

Techniques: In Vitro, Modification, Concentration Assay, Incubation

a The timeline of measurement on SD rats. b Photos of real-time monitoring of a healthy rat using ECLD, along with the photo of the marks left on the rat’s skin after the MNs are inserted. Real-time monitoring of ECL signal changes of cTnI in rats divided into c AMI model group, d AMI sham-surgery group, and e healthy group within 6 h wearing ECLD. Data presented as mean values ± SD with five parallel experiments. f Changes in OD value regarding cTnI concentration tested by ELISA kit in serum samples of three AMI model rats every 30 min. Real-time monitoring of ECL signal changes of cTnT in rats from g the AMI model group, h healthy group, and i AMI sham-surgery group within 6 h after wearing ECLD. Data presented as mean values ± SD with five parallel experiments. j Changes in OD value regarding cTnT concentration tested by ELISA kit in serum samples of three AMI model rats every 30 min. The stability of the ECL MN targeting cTnI in vivo on k the healthy group, l AMI sham-surgery group. Data presented as mean values ± SD with three parallel experiments. The stability of the ECL MN targeting cTnT in vivo on m the healthy group, n AMI sham-surgery group. Data presented as mean values ± SD with three parallel experiments. o The timeline of measurement on a Bama pig. p Photos of real-time monitoring of an AMI Bama pig using ECLD. q Photos of real-time monitoring of a healthy Bama pig using ECLD, along with the photo of the marks left on the Bama pig’s skin after the MNs are inserted. Real-time monitoring of ECL signal changes of cTnI in a Bama pig divided into r AMI model group and s healthy group within 16 h wearing ECLD. t Changes in OD value regarding cTnI concentration tested by ELISA kit in serum samples of an AMI Bama pig.

Journal: Nature Communications

Article Title: In situ electrochemiluminescence microneedle device for real-time biomarker monitoring in vivo

doi: 10.1038/s41467-026-70686-8

Figure Lengend Snippet: a The timeline of measurement on SD rats. b Photos of real-time monitoring of a healthy rat using ECLD, along with the photo of the marks left on the rat’s skin after the MNs are inserted. Real-time monitoring of ECL signal changes of cTnI in rats divided into c AMI model group, d AMI sham-surgery group, and e healthy group within 6 h wearing ECLD. Data presented as mean values ± SD with five parallel experiments. f Changes in OD value regarding cTnI concentration tested by ELISA kit in serum samples of three AMI model rats every 30 min. Real-time monitoring of ECL signal changes of cTnT in rats from g the AMI model group, h healthy group, and i AMI sham-surgery group within 6 h after wearing ECLD. Data presented as mean values ± SD with five parallel experiments. j Changes in OD value regarding cTnT concentration tested by ELISA kit in serum samples of three AMI model rats every 30 min. The stability of the ECL MN targeting cTnI in vivo on k the healthy group, l AMI sham-surgery group. Data presented as mean values ± SD with three parallel experiments. The stability of the ECL MN targeting cTnT in vivo on m the healthy group, n AMI sham-surgery group. Data presented as mean values ± SD with three parallel experiments. o The timeline of measurement on a Bama pig. p Photos of real-time monitoring of an AMI Bama pig using ECLD. q Photos of real-time monitoring of a healthy Bama pig using ECLD, along with the photo of the marks left on the Bama pig’s skin after the MNs are inserted. Real-time monitoring of ECL signal changes of cTnI in a Bama pig divided into r AMI model group and s healthy group within 16 h wearing ECLD. t Changes in OD value regarding cTnI concentration tested by ELISA kit in serum samples of an AMI Bama pig.

Article Snippet: Simulated interstitial fluid (Biochemazone, BZ254) was purchased from Chemazone Inc. (Canada). cTnI ELISA kit was obtained from ABclonal Biotechnology Co., Ltd. (Wuhan, China).

Techniques: Concentration Assay, Enzyme-linked Immunosorbent Assay, In Vivo

PEN treatment normalizes serum protein markers of cardiac injury (CK-MB, LDH, Cardiac troponin I) assessed by ELISA. Serum levels of cardiac markers were significantly increased by DOX, while PEN administration normalized them. DOX: Doxorubicin; PEN: Penicillamine; LDH: Lactic acid dehydrogenase; CK-MB: Creatine kinase-MB. *** p < 0.001, **** p < 0.0001, ns = non-significant.

Journal: Biomolecules

Article Title: Copper Chelation by Penicillamine Protects Against Doxorubicin-Induced Cardiomyopathy by Suppressing FDX1-Mediated Cuproptosis

doi: 10.3390/biom15091320

Figure Lengend Snippet: PEN treatment normalizes serum protein markers of cardiac injury (CK-MB, LDH, Cardiac troponin I) assessed by ELISA. Serum levels of cardiac markers were significantly increased by DOX, while PEN administration normalized them. DOX: Doxorubicin; PEN: Penicillamine; LDH: Lactic acid dehydrogenase; CK-MB: Creatine kinase-MB. *** p < 0.001, **** p < 0.0001, ns = non-significant.

Article Snippet: The serum levels of lactic dehydrogenase (LDH), creatine kinase MB (CK-MB), and cardiac troponin I (CTnI) were measured using commercially available kits: LDH assay endpoint kit (MG; Egypt, cat. no. MG283001 ), CK-MB ELISA kit (Elabscience, Houston, TX, USA, CAT: E-CL-R0722), and CTnI ELISA kit (Elabscience, Houston, TX, USA, CAT: E-EL-R1253).

Techniques: Enzyme-linked Immunosorbent Assay

Cardiac tissue contents of oxidative stress markers (glutathione peroxidase, malondialdyde and superoxide dismutase) in DOX and PEN-treated rats measured by ELISA. The DOX treatment induced an increase in MDA level with depletion of both SOD and GPx. PEN administration reversed these changes. DOX: doxorubicin; PEN: penicillamine; MDA: malondialdehyde; SOD: superoxide dismutase, GPx: glutathione peroxidase. ** p < 0.01, *** p < 0.001, **** p < 0.0001, ns = non-significant.

Journal: Biomolecules

Article Title: Copper Chelation by Penicillamine Protects Against Doxorubicin-Induced Cardiomyopathy by Suppressing FDX1-Mediated Cuproptosis

doi: 10.3390/biom15091320

Figure Lengend Snippet: Cardiac tissue contents of oxidative stress markers (glutathione peroxidase, malondialdyde and superoxide dismutase) in DOX and PEN-treated rats measured by ELISA. The DOX treatment induced an increase in MDA level with depletion of both SOD and GPx. PEN administration reversed these changes. DOX: doxorubicin; PEN: penicillamine; MDA: malondialdehyde; SOD: superoxide dismutase, GPx: glutathione peroxidase. ** p < 0.01, *** p < 0.001, **** p < 0.0001, ns = non-significant.

Article Snippet: The serum levels of lactic dehydrogenase (LDH), creatine kinase MB (CK-MB), and cardiac troponin I (CTnI) were measured using commercially available kits: LDH assay endpoint kit (MG; Egypt, cat. no. MG283001 ), CK-MB ELISA kit (Elabscience, Houston, TX, USA, CAT: E-CL-R0722), and CTnI ELISA kit (Elabscience, Houston, TX, USA, CAT: E-EL-R1253).

Techniques: Enzyme-linked Immunosorbent Assay